Each conductor element has an inspection probe hole and a center stop to ensure proper cable insertion. ABB's broad offering of connectivity and grounding solutions were designed to make the task of fastening, protecting, insulating and connecting wires easier and quicker for industrial applications, constructions, communications, utility and OEM professionals as well as do-it-yourself specialists. Add To Cart. You can come out of the Main Switch and go to the ground rod alone, and here you can use #6 wire, only to the rod. BURNDY Products Grounding US: 1-800-346-4175 www.burndy.com Canada: 1-800-387-6487 Throughout the catalog you will notice blue highlighted items. Aluminum Compression lugs and splice are dual rated for copper or aluminum wire and cable up to 1000 MCM. New Jersey. 1)Splicing of the wire-type grounding electrode conductor shall be permitted only by irreversible compression-type connectors listed as grounding and bonding equipment or by HYGROUND Grounding Irreversible Compression Splice; Heavy Duty; Accommodates: 4/0 AWG; 2.59 Length; Tin Plated The wire range on LENGTH 2.06 INCH. These aluminum compression lugs and splices are seamless, one piece, pure aluminum construction with tin-plating to assure maximum conductivity. And figures I could irreversible splice the ground in my panel and round the #6 up the same conduit as the rest of wires to the roof. $10.39 $9.04. The NEC Electrical Code that you may be referring to does not apply to your electrical wiring application. E-1 TABLE OF CONTENTS HYGROUND IRREVERSIBLE COMPRESSION GROUNDING AND INSTALLATION TOOLING Type YGIB. How to Splice Electrical Wires and the Ground. . MFR #: Y2825R. 2011 NEC revisions for grounding and bonding. Die index is 998. HYLINK Grounding Irreversible Compression Splice. May 13, 2007. Create a grounding path to Join Date: Apr 2006. Time to replace the wire likely. . Join two grounding wires to extend the length of your grounding connection or connect to an existing ground wire. Step 5 - Use a Splice Kit. These splice kits seal out moisture and prevent corrosion in above-ground and underground splices and splice connectors. CENTER WIRE STOP. Read: Price SCHRAIBERPUMP 4" DEEP WELL SUBMERSIBLE PUMP 1HP 230v 310FT 21GPM 134PSI (max) w/control 2 Years WARRANTY - STAINLESS STEEL DISCHARGE, CASING AND FLANGES, INCLUDES WIRE SPLICE KIT - model 42092M Best Hello. But they differ The use of a crimp sleeve is in essence an irreversible means, just like the acron clamps you can get where the head break off There are two wires that connect the switch to a phone type plug in the bottom BURNDY Hylink Grounding Compression Splice, 1-Stage Type YGHS Heavy Duty Irreversible, Stranded Copper Conductor, 2 AWG Conductor, 1.73 in Length, 1/2 in OD, Copper, Unplated Be sure to view everyday very best offer of SCHRAIBERPUMP 4" DEEP WELL SUBMERSIBLE PUMP 1HP 230v 310FT 21GPM During this process, a single wire that was layered between concrete and re-bar was cut. Yes, in practice it is probably better grounded as far a lightning or faults are concerned, but the code doesn't care. Acceptable for direct burial. Jun 12, 2007. Burndy YGHP34C26, Copper Compression Ground Rod Connector, 250 MCM Stranded - 500 MCM (Run), 5/8"- 3/4" Rod (Run), 1/0 AWG Stranded - 2/0 AWG Stranded (Tap), Direct Burial. H. Irreversible Compression Lugs: 1. The HYGROUND irreversible compression grounding system is a complete system of connectors for cross-grid connections, taps, splices, cable to ground rod, ground plates and terminations. Also reduces calculated total resistance of the system. . 91530 Figure 6 Irreversible Grounding Lug Connector 1-Hole #6 Tap. The grounding electrode conductor, which runs to any convenient grounding electrode [250.64 (F)], must not be spliced, except as permitted in (1) through (3): Splicing is Aluminum Compression Lugs. Yes you can splice a 14 gauge ground Outer Sleeve. A split bolt would be the easiest as long as it is listed for direct burial usage. splice into the existing ground wire, and run the new ground wire back to the new Main disconnect point. First, expose the individual conducting wires within the tough outer plastic jacket by using a cable ripper to slice through the sheathing. ground rod) or to any pre-existing GEC. They protect splicing on motor leads, power cables, pool wiring, rule #2 Ground wires need It's a great system, solid as a rock, and a pain in the butt if you ever have to break a splice. (1) Splicing shall be permitted only by irreversible compression-type connectors listed as grounding and bonding equipment or by the exothermic welding process. HYGROUND Grounding Irreversible Compression Splice; Heavy Duty; Accommodates: #2 AWG Use the expensive type ground lugs on each panel and each rail all tied together with a continuous #8 bare copper wire run down to an irreversible splice onto the Grounding Conductor (GEC) going to the ground-rod. Woudn't hurt to solder the splice either. Usually you can just splice the ground wire with wire nuts like every other conductor. He may not be correct, but always right. Underground Direct Burial Wire and Extension Cord Splice Kit for #10#12#14 AWG - 4 Wires - 4 Connectors, and 4 CLEAR Dual Wall 3M Heat Shrinks w/ 8" Long BLACK Heavy Dual Wall 1.1" Dia. Allows for economical bonding of reinforcing steel and water piping systems. Upvote #9 11-07-06, 12:43 PM J. jwhite. They protect splicing on motor leads, power cables, pool wiring, and more. Prefilled with PENETROX com-pound and strip sealed. Save Now! The large blue wire nuts ought to work. Burndy YGHP29C26, Copper Compression Ground Rod Connector, 1/0 - 250 MCM Stranded (Run), 1/2"- 5/8" Rod (Run), 1/0 AWG Stranded - 2/0 AWG Stranded (Tap), Direct Burial. You can also slide some pipe or plastic tubing on the wire BURNDY HYLINK YGHS28 1-Stage Type YGHS Heavy Duty Irreversible Grounding Compression Splice, 4/0 AWG Stranded Copper Conductor, 2.59 in L, Copper MFG Part #: Product Overview. Burndy Grounding Irreversible Compression Splice, 1/0 AWG YGS25. COMPRESSION GROUND SPLICE Irreversible compression 1/0 AWG STRANDED CONDUCTOR. Figure 8 Irreversible Grounding Connector. Splicing your GEC is permitted by irreversible compression-type I-beam ground clamp connectors Two-way splice connectors Ground plates Structural grounding studs Figure 6 to 6 compression grid and ground rod connectors Figure 6 to 8 compression Long bearing surface of clamp on ground wire secures ground connection Listed for direct burial Dimensions (in.) 5#12 wires C-4 Copper Compression Long Barrel Splice For making in-line irreversible splice connections of ground conductor Crimp with NSi & other industry standard tools Produced from high conductivity copper and tin plated GBIL 126-4414 Intersystem Grounding and Bonding Connector GLC-12 DB Heavy Duty Direct Bury oy In Ground Clamp SPLICE CLOSURES, TRAYS & ACCESSORIES. A.Locate parallel splice in appropriate wire gauge crimping die pocket and position tool on the center of the splice. no. Utilitech crimp connectors provide strong, vibration-resistant permanent connections in branch circuit and fixture wiring. Connect one wire to two wires of the same size. E-20 - E-21 All clamps provide 1-1/2" of contact area to ensure sufficient electrical contact for both ground. . $20 OFF Orders over $599 . For making in4ine irreversible splice connections of ground conductor Crimp with NSi & other industry standard tools Produced from high conductivity copper and tin plated Hole in top allows for single wire loop connection to enclosure/box Tokes max. The desire to use as little wire as possible, the smallest box as possible, is misguided at best. UL486A Listed. The biggest PITA I have has in my recent PV installation are irreversible ground splices. The conductor can be repaired, but, it must be repaired with an exothermic connection like a Cadweld or an irreversible crimp. A splice kit containing an inline connector will join the two ends of a break securely in a polyolefin sleeve, which will shrink when heat is applied, to It also looks like the electrician didn't do a great job because he never buried the wire, it is a bare wire and it just looks wrapped around the ground rod. Underground Direct Burial Wire and Extension cord Splice Kit for #10#12#14 AWG - 3 Wires, 3 Connectors and 3 CLEAR Dual Wall 3M Heat Shrinks With 8" long BLACK Heavy Dual Wall 1.1" ☎ +1 (838) 222-2203 Mon-Fri 8:00 AM - 5:00 PM ET or order online 24/7 Order YGHS27 by Burndy 25014244 Grounding Irreversible Compression Splice, (Pack of 10 pcs) - Mike Holt. . G. Splice Case Ground Accessories: Provide splice case grounding and bonding accessories manufactured by splice case manufacturer when available. Service-entrance conductors can be spliced or tapped per 110.14, 300.5(E), 300.13, and 300.15 [230.46]. While the NEC allows this, maintenance considerations often make this method inadvisable. While the NEC allows this, maintenance considerations often make this method inadvisable. joint,unless spliced only by irreversible compression-type connectors listed for the purpose or by the exothermic welding process. Allows permanent connections in branch circuit and fixture wiring. that you can install two ground rods spaced 6 foot apart. Burndy 25014244 Grounding Irreversible Compression Splice YGHS27. Grounding and Bonding Part 3 of 3. I'd start off considering a 4" square box. Pressure-type connection. If you're using the C-24 system--the crimp sleeve and the snap-on insulator cap--then you have to use the C-24 crimper. 07-26-2014, 11:46 AM. Member. C.Squeeze tool handles firmly. To help you complete your first RV wiring job safely and effectively, RV expert Dave Solberg and RVCA Master Technician Steve Albright walk you step by step through an RV wiring demonstration. When heat is applied, adhesive-lined insulation shrinks and bonds to the wires, creating a moisture- and corrosion-resistant seal. By code I think the connection has to be irreversible, but honestly a split bolt electrically would work here just fine. The irreversible rule (or splice free wire) applies to the grounding electrode conductor from the panel to a qualifying water pipe electrode (if any) and the GEC to one ground rod. B.Insert properly stripped wire (based on recommendations on package label) into each end of the parallel splice. There are some exceptions to this (notably with pool pumps) that require a CONTINOUS ground conductor free of removeable splices. #6. Its a simple circuit. Minimum order 1 each. Well-known member. Show them on the pictures where Originally posted by Mike90250 View Post. Providing a permanent watertight seal, our underground wire splice kits are perfect for direct burials. It might be easier to just replace it from the The conductors come in the back Copper wire only CTN QTY 10 10 10 10 10 6 6 *PT6515 adapter required with some tools. The local Description. ELECTRO TIN PLATED COPPER BODY. Description. 5. . 91522 Figure 8 Irreversible Grounding Lug Connector 3/4" 500-300. That is, grounding electrode conductor to be one wire, or added length of wire fused to the first one (not just spliced with a bolt.) ILSCOs offering of Irreversible Grounding Products has been enhanced to include several new RLT and GGB tin plated products for use with galvanized rod. (I think its 4) ground wire connects to the main panel I'll get a crimper and irreversible splice (crimp) my solid #6 to it and run it in the same conduit up to roof. Crimps #6 stranded through 1000 MCM copper or aluminum wire/cable. rule #1 The inspector is ALWAYS right. Wire Tracers, Underground Cable and Cable Locators . Used for bonding galvanized steel or aluminum cable trays to the grounding electrode system. 4.3 out of 5 stars 62. The use of structural metal as a grounding electrode is an issue that has been revised during several recent Code cycles. Do not use a utility knife, as you risk

irreversible ground wire splice